Operating Principle
The time delay is entirely pneumatic.
Air supply to the timing head is taken from ambient
atmosphere. The timing function is therefore independent of
line pressure. As a result, repeatability is unaffected by
variations in supply pressure, temperature, or
contaminations of supply.
|
|
Check these Features
- Snap acting poppet design operates on lubricated or
non-lubricated or dry air
- Timing unaffected by contaminants or fluctuations in
air line pressure
- Accurate ( +/- 2% repeatability), Easy to adjust
- Pressure range 40 - 120 PSI
- Temperature Range 5° - 140° F
- Fluids: Compressed air only
- High Flow
- In Line or Wall Mount
- 40 Micron Filtration Recommended
|
- CV-.17
- (1/8" Nominal Orifice)
|
Control Circuit Model
Subbase design for fast, easy replacement
with-out disturbing piping. 1/4" or 1/8" female NPT Ports for
easy connection to most circuits
Caution: These timers should
not be used where failure could result in personal injury or
damage |
|
Ordering
Information |
| KAT-PRT-*10- |
1/8" |
Port Size |
| 1/4" |
|
|
Time Range |
Description |
|
*E |
.1-3 Seconds NNP |
|
*A |
.1-30 Seconds NNP |
|
*B |
10-180 Seconds NNP
|
|
*F |
.1-3 Seconds NP |
|
*C |
.1-30 Seconds NP |
|
*D |
10-180 Seconds NP |
|
- NNP = Normally Non Passing
- NP = Normally Passing
|
|
|
 |
Intermediate Flow Inline
Model
- Available 1/4" or 3/8"
- Internal or External Pilot
- Speciation Pressure Range 40 - 120 PSI
- Temperature 5° - 140° F
- Fluids: Compressed Air Only
|
|
Ordering
Information |
|
KAT-*-55-** |
|
Time Range |
Description |
|
*E |
.1-3 Seconds |
|
*A |
.1-30 Seconds |
|
*B |
10-180 Seconds
|
|
| Series and Size |
Cv
|
|
** 11 = 1/4" NNP
|
1.4 |
|
** 12 = 3/8" NNP |
1.6 |
|
** 21 = 1/4" NP |
1.8 |
|
** 22 = 3/8" NP |
2.2 |
|
|
- NNP = Normally Non Passing
- NP = Normally Passing
|
|
|
 |
High Flow Inline Model
Available in Three Sizes
-
3/8" Cv = 4.2
-
1/2" Cv = 4.6
-
3/4" Cv = 5.0
|
|
Ordering
Information |