Kober Timers
Three Unique Pneumatic Timers

Operating Principle

The time delay is entirely pneumatic. Air supply to the timing head is taken from ambient atmosphere. The timing function is therefore independent of line pressure. As a result, repeatability is unaffected by variations in supply pressure, temperature, or contaminations of supply.


Check these Features
  • Snap acting poppet design operates on lubricated or non-lubricated or dry air
  • Timing unaffected by contaminants or fluctuations in air line pressure
  • Accurate ( +/- 2% repeatability), Easy to adjust
  • Pressure range 40 - 120 PSI
  • Temperature Range 5° - 140° F
  • Fluids: Compressed air only
  • High Flow
  • In Line or Wall Mount
  • 40 Micron Filtration Recommended

CV-.17
(1/8" Nominal Orifice)

Control Circuit Model

Subbase design for fast, easy replacement with-out disturbing piping. 1/4" or 1/8" female NPT Ports for easy connection to most circuits

Caution: These timers should not be used where failure could result in personal injury or damage

Ordering Information

KAT-PRT-*10- 1/8" Port Size
1/4"

Time Range

Description

*E   .1-3 Seconds NNP
*A   .1-30 Seconds NNP
*B   10-180 Seconds NNP    
*F   .1-3 Seconds NP
*C   .1-30 Seconds NP
*D   10-180 Seconds NP
NNP = Normally Non Passing
NP = Normally Passing

Intermediate Flow Inline Model

  • Available 1/4" or 3/8"
  • Internal or External Pilot
  • Speciation Pressure Range 40 - 120 PSI
  • Temperature 5° - 140° F
  • Fluids: Compressed Air Only

Ordering Information

KAT-*-55-**

Time Range

Description

*E   .1-3 Seconds
*A   .1-30 Seconds
*B   10-180 Seconds    
Series and Size   Cv   
 ** 11 = 1/4" NNP     1.4
 ** 12 = 3/8" NNP 1.6
 ** 21 = 1/4" NP 1.8
 ** 22 = 3/8" NP 2.2
NNP = Normally Non Passing
NP = Normally Passing

High Flow Inline Model

Available in Three Sizes

  • 3/8" Cv = 4.2

  • 1/2" Cv = 4.6

  • 3/4" Cv = 5.0

Ordering Information

KAT-*-56-**

Time Range

Description

*E   .1-3 Seconds
*A   .1-30 Seconds
*B   10-180 Seconds    
Series and Size   Cv   
 ** 52 = 3/8" NNP     4.4
 ** 53 = 1/2" NNP 5.0
 ** 57 = 3/4" NNP 5.4
 ** 82 = 3/8" NP 4.6
 ** 83 = 1/2" NP 5.1
 ** 87 = 3/4" NP 5.7
NNP = Normally Non Passing
NP = Normally Passing
Tamper Proof Cap: Order Part #LA9D901 (Fits All Models)

To receive Information, Training or a Product Demonstration
© Fluidtrols Corporation. 2004