PIAB's Classic
Series Pumps
|
|
PIAB's L Series Vacuum
Pumps are designed with the packaging industry in mind. These pumps provide 30%-70% more
vacuum flow . The L Series will handle high leakage rates in applications such as opening
and handling cartons or cases while still providing enough vacuum pressure to get the job
done.
The Low Pressure M Series vacuum pumps
will provide 27 -inHg of vacuum at only 49 psi inlet pressure. Finally, there is an
air-driven multi-ejector vacuum pump that can handle low or fluctuating compressed air
pressures while still providing a deep vacuum level.
|
|
|
Are you having
trouble finding PIAB's Classic series pumps, the low-pressure M and
the High-Flow L, because all PIAB's pumps look the same?
Well, PIAB has been busy painting the face plates.
Now the Low-Pressure M pumps have a red-colored face plate and the
High-Flow L pumps will sport a blue-colored face plate.
|
|
|
(For more information, see the difference
between a Sealed and
Non-sealed systems)
-
Very good chemical resistance which means increased safety
and reliability.
-
Light weight (has been reduced by 35% compared to MLD).
-
Increased range of types and sizes (X-series).
-
In many cases replaces mechanical displacement pumps of
costly design.
-
Improved vacuum performance (applies to H pumps).
-
The mounting set is made of stainless steel instead of
aluminum to give more resistance to chemicals.
-
Very low sound level. At maximum load, is is a mere 60 dB (A)
-
5-year warranty.
-
Take advantage of our free trial and experience PIAB's advance vacuum technology.
- These pumps are especially suitable for industrial
applications where the environment is harsh. With the
- correct seal material the pumps can
be used in environments containing chlorine solvents, petrol, oil, alcohol, anti freeze
(ethylene glycol), etc.
Some examples of applications are:
-
Evacuation of corrosive or aggressive vapors from container.
-
Fish and dairy industries using salt in their processes.
Normally signify problems of corrosion.
-
Degassing.
-
Recycling of solvents.
-
The low weight of the pump is conducive to mounting on robot
arms and in other applications where weight is a factor.
|
- Choosing the right pump is simple
|
|
Vacuum Flow
Vacuum flow in scfm at different vacuum levels (-inHg) |
| Series |
Model/Design |
- Feed
- Pressure
- psi
|
0 |
3 |
6 |
9 |
12 |
15 |
18 |
21 |
24 |
27 |
28 |
| L |
- Classic L25
- Classic L50
- Classic L100
|
- 87
- 87
- 87
|
- 13
- 22
- 32
|
- 6.99
- 13.14
- 22.04
|
- 4.87
- 9.32
- 16.53
|
- 3.28
- 6.15
- 11.23
|
- 1.76
- 3.52
- 6.89
|
- 1.34
- 2.65
- 5.30
|
- 0.95
- 1.91
- 3.81
|
- 0.59
- 1.19
- 2.37
|
- -
- -
- -
|
- -
- -
- -
|
- -
- -
- -
|
| M |
- Classic M25
- Classic M25LP
- Classic M50
- Classic M50LP
- Classic M100
- Classic M100LP
|
- 87
- 49
- 87
- 49
- 87
- 49
|
- 14
- 13
- 23
- 22
- 33
- 32
|
- 7.63
- 5.80
- 13.77
- 11.40
- 22.46
- 19.10
|
- 5.09
- 4.24
- 9.75
- 8.26
- 15.89
- 14.20
|
- 2.54
- 2.59
- 5.09
- 5.19
- 10.17
- 9.54
|
- 1.27
- 1.44
- 2.54
- 2.88
- 5.09
- 5.76
|
- 0.93
- 1.12
- 1.89
- 2.25
- 3.81
- 4.49
|
- 0.64
- 0.85
- 1.27
- 1.70
- 2.54
- 3.39
|
- 0.34
- 0.57
- 0.70
- 1.14
- 1.38
- 2.29
|
- 0.16
- 0.23
- 0.32
- 0.47
- 0.64
- 0.93
|
- -
- -
- -
- -
- -
- -
|
- -
- -
- -
- -
- -
- -
|
| MLD |
- Classic MLD25
- Classic MLD50
- Classic MLD100
|
- 87
- 87
- 87
|
- 14
- 23
- 33
|
- 7.6
- 14
- 22
|
- 5.1
- 9.7
- 16
|
- 2.5
- 5.1
- 10
|
- 1.3
- 2.5
- 5.1
|
- 0.93
- 1.9
- 3.8
|
- 0.64
- 1.3
- 2.5
|
- 0.34
- 0.7
- 1.4
|
- 0.16
- 0.32
- 0.64
|
- 0.26
- 0.053
- 0.11
|
- -
- -
- -
|
| H |
- Classic H40
- Classic H120
|
- 87
- 87
|
- 6.4
- 18.2
|
- 5.1
- 14.8
|
- 3.7
- 10.8
|
- 2.3
- 7.0
|
- 1.1
- 3.7
|
- 0.7
- 2.75
|
- 0.5
- 1.9
|
- 0.34
- 1.4
|
- 0.25
- 0.95
|
- 0.13
- 0.28
|
- 0.042
- 0.13
|
|
|
|
Evacuation Time
Vacuum flow in scfm at different vacuum levels
(-inHg) |
| Series |
Model/Design |
- Feed
- Pressure
- psi
|
3 |
6 |
9 |
12 |
15 |
18 |
21 |
24 |
27 |
28 |
| L |
- Classic L25
- Classic L50
- Classic L100
|
- 87
- 87
- 87
|
- 0.48
- 0.37
- 0.20
|
- 1.36
- 0.82
- 0.45
|
- 2.80
- 1.53
- 0.85
|
- 5.2
- 2.8
- 1.6
|
- 9.6
- 5.0
- 2.5
|
- 15
- 7.6
- 3.8
|
- 24
- 12
- 6.1
|
- -
- -
- -
|
- -
- -
- -
|
- -
- -
- -
|
| M |
- Classic M25
- Classic M25LP
- Classic M50
- Classic M50LP
- Classic M100
- Classic M100LP
|
- 87
- 49
- 87
- 49
- 87
- 49
|
- 0.45
- 0.57
- 0.34
- 0.37
- 0.20
- 0.23
|
- 1.25
- 1.59
- 0.74
- 0.91
- 0.45
- 0.51
|
- 2.83
- 3.40
- 1.42
- 1.76
- 0.71
- 0.91
|
- 6.7
- 6.8
- 3.3
- 3.4
- 1.7
- 1.8
|
- 12
- 12
- 6.2
- 6.0
- 3.1
- 3.1
|
- 21
- 19
- 10
- 9.3
- 5.2
- 4.7
|
- 35
- 29
- 17
- 14
- 8.7
- 7.2
|
- 62
- 46
- 31
- 23
- 16
- 12
|
- 152
- 130
- 76
- 65
- 38
- 33
|
- -
- -
- -
- -
- -
- -
|
| MLD |
- Classic MLD25
- Classic MLD50
- Classic MLD100
|
- 87
- 87
- 87
|
- 0.45
- 0.34
- 0.20
|
- 1.2
- 0.74
- 0.45
|
- 2.8
- 1.4
- 0.7
|
- 6.7
- 3.3
- 1.7
|
- 12
- 6.2
- 3.1
|
- 21
- 10
- 5.2
|
- 35
- 17
- 8.7
|
- 62
- 31
- 16
|
- 152
- 76
- 38
|
- -
- -
- -
|
| H |
- Classic H40
- Classic H120
|
- 87
- 87
|
- 0.85
- 0.34
|
- 2.0
- 0.71
|
- 3.4
- 1.42
|
- 7.1
- 2.7
|
- 15.6
- 4.8
|
- 26
- 7.7
|
- 41.1
- 11.2
|
- 62.3
- 17
|
- 96.3
- 33.4
|
- 141.6
- 52.1
|
|
|
To receive Information, Training or a Product Demonstration.
© Fluidtrols Corporation. 2004
|